testo 184 G1 – Vibration, humidity and temperature data logger
Product Description
With the data loggers testo 184 G1 for shock, humidity and temperature, you can now monitor the transport of sensitive products such as electronics , art, pharmaceuticals or foods over an unlimited operating time. More info on applications (link to tab Applications)
At their destination, a glance at the display or the LEDs tells you whether the configured limit values have been adhered to. In order to obtain detailed information, it is sufficient to connect the logger to a PC – a PDF report is immediately generated with all relevant data. In order for you to be able to work even more efficiently and conveniently with the data loggers, all required files and information are stored directly and securely in the testo 184 G1: Configuration file, instruction manual and PDF report of your recorded data.
The measurement value store of the data logger testo 184 G1 for shock has a capacity of 1000 measurement values, for humidity and temperature 64000 measurement values. The measurement rate is freely selectable from 1 min to 24 h. The battery has a life of 120 days. The temperature data logger testo 184 G1 is supplied by a standard battery which can be exchanged by the user.
testo 184 G1 is compliant with GxP, 21 CFR Part 11 and HACCP. Testo AG is an ISO 9001:2008-certified company, and ensures the adherence to the norms through internal audits as well as accredited external audits.
Technical Data | |
Temperature – NTC | |
Measuring range | -20 to +70 °C |
Accuracy | ±0.5 °C (0 to +70 °C) |
±0.8 °C (-20 to 0 °C) | |
Resolution | 0.1 °C |
Reaction time | t₉₀ = 30 min |
Measuring rate | 1 min to 24 h |
Humidity – Capacitive | |
Measuring range | 0 to 100 %RH |
Accuracy | ±1.8 %RH, +3 % of mv (at 25 °C, 5 % to 80 %RH) |
±0.03 %RH/K (at 0 to 60 °C) | |
±1 %rF Hysterese | |
±1 %rF/year Drift | |
Resolution | 0.1 %RH |
Measuring rate | 1 min to 24 h |
Shock | |
Measuring range | 0 to 27 g |
0 to 265 m/s² | |
Accuracy | ±(0.1 g + 5 % of mv) |
±1 / 1 / 1 m/s² | |
Resolution | 0.1 g |
1 m/s² | |
1 m/s² | 1 s |
General technical data | |
Weight | 44 g |
Dimensions | 40 x 12.5 x 96.5 mm (LxWxH) |
Operating temperature | -20 to +70 °C |
Product-/housing material | ABS |
Protection class | IP30 |
System requirements | Adobe® Acrobat Reader |
Product colour | white |
Standards | CE 2014/30/EU; DIN EN 61326-1:2013; DIN EN 50581:2013; CFR 21 Part 1 |
Channels | 5 internal |
Operating time | Unlimited |
Authorizations | CE |
Alarm function | via LED and Display |
Battery type | Lithium battery CR2450, 3V, exchangeable |
Battery life | 120 days (at +25 °C and 15 min. meas. cycle). |
Display type | segment LCD |
Display size | one-line |
Display ligthing | No |
Interface | USB; NFC |
Memory | 64,000 measuring values |
Storage temperature | -55 to +70 °C |