STACK 181 WS Particulate Measurement System

Product Descriptions
The PCME STACK 181 WS is suitable for measuring particulate emissions from wet scrubbers and other processes where the flue gas falls below dew point (cold stack conditions) or water droplets are present. The extractive instrument takes a representative continuous sample from the stack, heats this well above dew point to evaporate water droplets and then measures the particulate concentration under dry conditions. This extractive approach with heating overcomes the problems of interference from condensation and water droplets associated with using in-situ particulate monitors after wet collectors.

The PCME STACK 181 WS uses an advanced ProScatter Forward Scatter sensor (PCME QAL 181) which is certified by TUV and MCERTS as QAL1 compliant. With certification ranges covering both 0-15mg/m3 and 0-100mg/m3, the sensor is suitable for monitoring the highly abated emissions found after Flue Gas Desulphurisation plant (FGD). The instrument is able to monitor saturated flue gas which is critical for the application of monitoring emissions from a coal fired power plant fitted with a wet FGD system and meets the requirements of PS-11 and EN 14181.

Resolution and Sensitivity

The PCME QAL 181 sensor within the PCME STACK 181 WS uses a low-angle forward light scattering measurement principle unique to PCME (see ProScatter™ Forward Scatter). The measured ‘cone’ of scattered light is larger than in typical light scatter instruments, which provides:
– Excellent sensing resolution and sensitivity, due to an increased signal-to-noise ratio.
– Reduced cross-sensitivity to changing particle size, allowing a greater range of applications for which the instrument is suitable

หากท่านสนใจกรุณากรอกรายละเอียด

Related Searches:

LSI : Soil moisture and temperature

Sensors for measuring the temperature and volumetric content of water. Series of sensors designed to measure inside soils or other porous materials.

LSI : Atmospheric pressure

Barometric pressure sensor made for easy integration to third parties systems with accurate pressure measurement. Barometer. 0-1 Vdc output.

LSI : Sunshine duration

The sensor measures sunshine duration and direct radiation from the sun. Measurement is made with a second class WMO pyranometer.

LSI : Luxmeter

Luxmetric probes to measure illuminance in long-term outdoor applications with the same response as the human eye (Vlamba CIE curve).

Chat with us on LINE

เราใช้คุกกี้เพื่อพัฒนาประสิทธิภาพ และประสบการณ์ที่ดีในการใช้เว็บไซต์ของคุณ คุณสามารถศึกษารายละเอียดได้ที่ นโยบายความเป็นส่วนตัว และสามารถจัดการความเป็นส่วนตัวเองได้ของคุณได้เองโดยคลิกที่ ตั้งค่า

Privacy Preferences

คุณสามารถเลือกการตั้งค่าคุกกี้โดยเปิด/ปิด คุกกี้ในแต่ละประเภทได้ตามความต้องการ ยกเว้น คุกกี้ที่จำเป็น

Allow All
Manage Consent Preferences
  • คุกกี้ที่จำเป็น
    Always Active

    ประเภทของคุกกี้มีความจำเป็นสำหรับการทำงานของเว็บไซต์ เพื่อให้คุณสามารถใช้ได้อย่างเป็นปกติ และเข้าชมเว็บไซต์ คุณไม่สามารถปิดการทำงานของคุกกี้นี้ในระบบเว็บไซต์ของเราได้

  • คุกกี้เพื่อการวิเคราะห์

    คุกกี้ประเภทนี้จะทำการเก็บข้อมูลการใช้งานเว็บไซต์ของคุณ เพื่อเป็นประโยชน์ในการวัดผล ปรับปรุง และพัฒนาประสบการณ์ที่ดีในการใช้งานเว็บไซต์ ถ้าหากท่านไม่ยินยอมให้เราใช้คุกกี้นี้ เราจะไม่สามารถวัดผล ปรังปรุงและพัฒนาเว็บไซต์ได้

Save