เครื่องวิเคราะห์ Ammonium รุ่น Alyza IQ NH4

Product Descriptions
Ammonium Analyzer for the IQ SENSOR NET

The perfect solution for monitoring ammonium in the treatment plant effluent as well as surface water bodies – on-site analyzer for ammonium measurement in the IQ SENSOR NET:

• Minimized reagent consumption and waste
• Reliable results even at very low NH4 concentrations
• Minimum maintenance
• Easy to operate
• Compatible with IQ SENSOR NET

The Alyza IQ NH4 ammonium analyzer is the latest addition to the IQ SENSOR NET. It can be easily integrated into new and existing systems just as simple as a sensor. The measuring principle is based on the photometric indophenol method according to DIN 38 406, which has been a proven detection method for ammonium. Thanks to the wet chemical measurement directly in the process, Alyza IQ is the perfect solution for monitoring the treatment plant effluent as well as surface water bodies.

Highlights:

• Minimized reagent consumption and waste
Alyza IQ boasts an extremely low use of reagents – an advantage that significantly reduces operating costs and waste generation
• Simple Service
Regular maintenance takes only 10 minutes every 2-3 months.
• Reliable results from low to high measuring levels
Thanks to the new technology, Alyza IQ provides an accurate and reliable measurement over the whole range of 0.02-5.00 mg/l and 0.10250.00 mg/l NH4-N.
• Automatic cleaning and calibration with standards
The fully automated cleaning as well as 2-point calibration with selectable intervals ensures an exceptional degree of operational safety.
• On-site installation
Alyza IQ NH4 can be installed directly at the basin. This guarantees short transport distances and promptly measured values. Thanks to the climate package, the analyzer is perfectly suited for all weathers.

Measurement method Berthelot method (Indophenol method)
Measurement range Two measuring ranges
MR1:
Displayed:
Resolution:
Accuracy:
0.02 … 5.00 mg/l NH4-N
0.00 … 5.00 mg/l NH4-N
0.01 mg/l NH4-N
± 2 % ± 0.02 mg/l
MR2:
Displayed:
Resolution:
Accuracy:
0.10 … 20.00 mg/l NH4-N
0.00 … 20.00 mg/l NH4-N
0.01 mg/l NH4-N
± 3 % ± 0.10 mg/l
Sample streams/channels 1 channel
Cleaning Automatic cleaning with cleaning solutions
Calibration Automatic 1- and 2-point calibrations
Operational temperature -4 … 104 °F (-20 … +40) °C

หากท่านสนใจกรุณากรอกรายละเอียด

Related Searches:

LSI : Soil moisture and temperature

Sensors for measuring the temperature and volumetric content of water. Series of sensors designed to measure inside soils or other porous materials.

LSI : Atmospheric pressure

Barometric pressure sensor made for easy integration to third parties systems with accurate pressure measurement. Barometer. 0-1 Vdc output.

LSI : Sunshine duration

The sensor measures sunshine duration and direct radiation from the sun. Measurement is made with a second class WMO pyranometer.

LSI : Luxmeter

Luxmetric probes to measure illuminance in long-term outdoor applications with the same response as the human eye (Vlamba CIE curve).

Chat with us on LINE

เราใช้คุกกี้เพื่อพัฒนาประสิทธิภาพ และประสบการณ์ที่ดีในการใช้เว็บไซต์ของคุณ คุณสามารถศึกษารายละเอียดได้ที่ นโยบายความเป็นส่วนตัว และสามารถจัดการความเป็นส่วนตัวเองได้ของคุณได้เองโดยคลิกที่ ตั้งค่า

Privacy Preferences

คุณสามารถเลือกการตั้งค่าคุกกี้โดยเปิด/ปิด คุกกี้ในแต่ละประเภทได้ตามความต้องการ ยกเว้น คุกกี้ที่จำเป็น

Allow All
Manage Consent Preferences
  • คุกกี้ที่จำเป็น
    Always Active

    ประเภทของคุกกี้มีความจำเป็นสำหรับการทำงานของเว็บไซต์ เพื่อให้คุณสามารถใช้ได้อย่างเป็นปกติ และเข้าชมเว็บไซต์ คุณไม่สามารถปิดการทำงานของคุกกี้นี้ในระบบเว็บไซต์ของเราได้

  • คุกกี้เพื่อการวิเคราะห์

    คุกกี้ประเภทนี้จะทำการเก็บข้อมูลการใช้งานเว็บไซต์ของคุณ เพื่อเป็นประโยชน์ในการวัดผล ปรับปรุง และพัฒนาประสบการณ์ที่ดีในการใช้งานเว็บไซต์ ถ้าหากท่านไม่ยินยอมให้เราใช้คุกกี้นี้ เราจะไม่สามารถวัดผล ปรังปรุงและพัฒนาเว็บไซต์ได้

Save