Fidas200 : dust measurement device

Product Descriptions
Fidas® 200 EN 16450 approved fine dust measurement device for simultaneous measurement of PM2.5 and PM10

• Type-approved and certified according to latest EN requirements (EN 15267)
• Continuous and simultaneous real-time measurement of multiple PM values
• Additional information on particle number concentration and particle size distribution
• Adjustable time resolution from > 1 s to 24 h
• Light source: LED with high stability and long lifetime
• Long service life
• Low maintenance
• External check of calibration on site possible
• Intuitive and easy to operate
• Reliable function, very high data availability (> 99 %)
• 2 pumps in parallel operation for additional operational safety due to redundancy
• Permanent monitoring of status, among others online monitoring of calibration
• Remote monitoring, maintenance and control easily possible
• Cloud zone via Palas server for worldwide data retrieval
• No radioactive material
• No consumables
• Low energy consumption
• Reduces your operating expenses

Interfaces USB, Ethernet (LAN), RS232, Wi-Fi
Measurement range (size) 0.18 – 18 µm
3 measurement ranges
Size channels 64 (32/decade)
Measuring principle Optical light scattering of single particles
Measurement range (number CN) 0 – 20.000 particles/cm3
Volume flow 4.8 l/min ≙ 0.3 m3/h ± 3% (24h), complient with EN 16450
Data acquisition Digital, 20 MHz processor, 256 raw data channels
Light source LED
Power supply 115/230 V, 50/60 Hz
User interface Touchscreen, 800 * 480 pixel, 7″ (17.78 cm)
Dimensions 450 * 320 * 180.5 mm (H * W * D), 19″
Weight Control unit: 9.3 kg
Sample head: 2.25 kg
Sample tube: 4.50 kg
Operating system Windows
Data logger storage Capacity for 2 years continuous operation at 60 s storage interval
Software PDAnalyze Fidas®
Measurement range (mass) Measurement range (mass)
Installation conditions +5 – +40 °C
Sampling head Passive collector Sigma-2
Response time (sensor) < 2s
Linearity 1.06 for PM2.5 1.03 for PM10
(against gravimetry according to EN16450, TÜV Report)
Sampling System Drying of the aerosol by IADS
(Intelegent Aerosol Drying System)
Accuracy R2 > 0,98 for PM2.5 and R2> 0,94 for PM10
versus EN16450-certified Fidas® 200
(15 min average, each)
Data PM1, PM2.5, PM4, PM10, PMTotal , Cn, particle size distribution,
air pressure, air temperature, relative humidity
Noise emission < 70 dB(A)
Fuse T2A
Resolution 0.1 µg/m3
Power consumption Normal operation: 60 W
Maximal: 200 W
Housing Table housing, optionally with mounting brackets for rack-mounting

• Regulatory pollution control in monitoring networks
• Ambient air monitoring campaigns
• Long-term studies
• Emission source attribution
• Emission dispersion studies (e.g. fires, volcanoes)

หากท่านสนใจกรุณากรอกรายละเอียด

Related Searches:

Multi EyeCGas

Optical Gas Detector for Methane, Hydrocarbons, more than 400 VOCs and CO2

EyeCSite QOGI

Real-time and offline Optical Gas Imaging quantification SW, Easy to operate software adapted to theinspection workflow

EyeCGas 2.0 Long Range

Optical Gas Detector for Methane, Hydrocarbons, more than 400 VOCs and CO2, IR Resolution: 320 x 240 pixels

EyeCGas CO/CO2

Hand-held, high sensitivity Optical Gas imaging For CO & CO2 detection, handheld OGI camera for CO gas leak detection.

Chat with us on LINE

เราใช้คุกกี้เพื่อพัฒนาประสิทธิภาพ และประสบการณ์ที่ดีในการใช้เว็บไซต์ของคุณ คุณสามารถศึกษารายละเอียดได้ที่ นโยบายความเป็นส่วนตัว และสามารถจัดการความเป็นส่วนตัวเองได้ของคุณได้เองโดยคลิกที่ ตั้งค่า

Privacy Preferences

คุณสามารถเลือกการตั้งค่าคุกกี้โดยเปิด/ปิด คุกกี้ในแต่ละประเภทได้ตามความต้องการ ยกเว้น คุกกี้ที่จำเป็น

Allow All
Manage Consent Preferences
  • คุกกี้ที่จำเป็น
    Always Active

    ประเภทของคุกกี้มีความจำเป็นสำหรับการทำงานของเว็บไซต์ เพื่อให้คุณสามารถใช้ได้อย่างเป็นปกติ และเข้าชมเว็บไซต์ คุณไม่สามารถปิดการทำงานของคุกกี้นี้ในระบบเว็บไซต์ของเราได้

  • คุกกี้เพื่อการวิเคราะห์

    คุกกี้ประเภทนี้จะทำการเก็บข้อมูลการใช้งานเว็บไซต์ของคุณ เพื่อเป็นประโยชน์ในการวัดผล ปรับปรุง และพัฒนาประสบการณ์ที่ดีในการใช้งานเว็บไซต์ ถ้าหากท่านไม่ยินยอมให้เราใช้คุกกี้นี้ เราจะไม่สามารถวัดผล ปรังปรุงและพัฒนาเว็บไซต์ได้

Save