BTS2048-VL LED Spectroradiometer

Product Descriptions
Versatile High Speed and High Quality LED Spectroradiometer
• Bi-Tec sensor* : Dual sensor for more accurate measurements
• Light meter for LED flash binning
• Very short measuring times (electronic shutter), high dynamic range (filter wheel)
• Trigger inputs and outputs, Ethernet and USB for fast data transmission
• Direct input optics with diffuser for illuminance and spectral irradiance. Expandable with integrating sphere for luminous flux and spectral irradiance.

  Specifications
  General
  Short description High speed spectroradiometer with a wide dynamic range for CW and pulsed measurements of irradiance/illuminance, spectrum, luminous color, and color rendering index. Accessories for measurement of other parameters
  Main features Compact device. BiTec detector with back-thinned CCD (2048 pixels, 2 nm optical bandwidth, electronic shutter) and Si-photodiode with V(lambda) filter. Optical bandwidth correction (CIE214). Filter wheel with shutter and attenuation filters. Input lens with a diffusor window that has a cosine field of view. Automatic PWM synchronization
  Measurement range Spectral: 300 nm to 1050 nm, 1 lx to 3E8 lx (min. level by white LED with low saturation)
Integral: photometric 360 nm to 830 nm, 0.1 lx Noise signal up to 3E8 lx
  Typical applications CCD spectroradiometer for design applications. Module for integration in test systems for front-end and back-end LED binning.
  Calibration Factory calibration. Traceable to international calibration standards
  Product
  Measured Quantity Spectral irradiance (W/(m² nm)), irradiance (W/m²), illuminance (lx), spectral radiant intensity (W/(sr nm)), radiant Intensity (W/sr), luminous intensity (cd), dominant wavelength, peak wavelength, center wavelength, centroid wavelength, x, y, u´, v´, X,Y,Z, delta uv, color temperature, color rendering index (CRI) Ra, R1-R15, TM-30-20, CIE224, CQS, CIE170, etc.. Option integrating sphere: in addition spectral flux (W/nm) and luminous flux (lm) Option goniometer: in addition radiant intensity (W/sr) distribution and luminous intensity (cd) distribution
  Sensor Accuracy class B according to DIN 5032 and CIE No. 69
Accuracy class A for f1`, u, f3 and f4 according to DIN 5032 and CIE No. 69
  Input optics Diffusor, cosine corrected field of view (f2 ≤ 3 %)
  Filter wheel 4 positions (open, closed, OD1, OD2). Use for remote dark current measurement and dynamic range extension.
  BiTec Parallel measurement with diode and array is possible, thereby linearity correction of the array through the diode and online correction of the spectral mismatch of the diode through a*(sz(λ)) respectively F*(sz(λ)).
  Spectral Detector
  Spectral range (280 -1050) nm, see limitation for calibration
  Optical Bandwidth 2 nm
  Pixel resolution ~0.4 nm/Pixel
  Number of pixels 2048
  Chip Highly sensitive back-thinned CCD chip
  ADC 16bit (25 ns instruction cycle time)

หากท่านสนใจกรุณากรอกรายละเอียด

Related Searches:

กล้องตรวจจับก๊าซ Multi EyeCGas

ข้อมูลคุณสมบัติSpecificationsข้อมูล EyeCGas® Multi กล้องตรวจจับก๊าซ (Optical Gas Imaging) แบบพกพา สำหรับก๊าซมีเทน, ก๊าซไฮโดรคาร์บอน, [...]

EyeCSite QOGI

Real-time and offline Optical Gas Imaging quantification SW, Easy to operate software adapted to theinspection workflow

EyeCGas 2.0 Long Range

Optical Gas Detector for Methane, Hydrocarbons, more than 400 VOCs and CO2, IR Resolution: 320 x 240 pixels

EyeCGas CO/CO2

Hand-held, high sensitivity Optical Gas imaging For CO & CO2 detection, handheld OGI camera for CO gas leak detection.

Chat with us on LINE

เราใช้คุกกี้เพื่อพัฒนาประสิทธิภาพ และประสบการณ์ที่ดีในการใช้เว็บไซต์ของคุณ คุณสามารถศึกษารายละเอียดได้ที่ นโยบายความเป็นส่วนตัว และสามารถจัดการความเป็นส่วนตัวเองได้ของคุณได้เองโดยคลิกที่ ตั้งค่า

Privacy Preferences

คุณสามารถเลือกการตั้งค่าคุกกี้โดยเปิด/ปิด คุกกี้ในแต่ละประเภทได้ตามความต้องการ ยกเว้น คุกกี้ที่จำเป็น

Allow All
Manage Consent Preferences
  • คุกกี้ที่จำเป็น
    Always Active

    ประเภทของคุกกี้มีความจำเป็นสำหรับการทำงานของเว็บไซต์ เพื่อให้คุณสามารถใช้ได้อย่างเป็นปกติ และเข้าชมเว็บไซต์ คุณไม่สามารถปิดการทำงานของคุกกี้นี้ในระบบเว็บไซต์ของเราได้

  • คุกกี้เพื่อการวิเคราะห์

    คุกกี้ประเภทนี้จะทำการเก็บข้อมูลการใช้งานเว็บไซต์ของคุณ เพื่อเป็นประโยชน์ในการวัดผล ปรับปรุง และพัฒนาประสบการณ์ที่ดีในการใช้งานเว็บไซต์ ถ้าหากท่านไม่ยินยอมให้เราใช้คุกกี้นี้ เราจะไม่สามารถวัดผล ปรังปรุงและพัฒนาเว็บไซต์ได้

Save