855 SOFC Test System

Product Descriptions
The 855 SOFC Test system is an integrated, turn-key Solid Oxide Fuel Cell Test System. This unit has a zero volt capability for lower measurement range. The addition of a programmable Power Supply extends the 855’s capabilities to include electrolysis mode. Automated, hands-free switching between SOFC and SOEC mode via FuelCell® software. The 855 SOFC system is known for it’s high performance and accuracy.

FuelCell® Software and Experimental Methods Manual are included. Optional Impedance Spectroscopy & HFR.

• Suitable for Button Cells and Planar Cells
• Multi Range Electronic load 5/25/50 A, 100 W, 20 V
• FuelCell® software for user-friendly computer controlled cell operation & experimentation
• Stainless Steel Anode humidifier with Bypass Valve and auto waterfill
• Programmable Power Supply for SOEC mode operation – 100 A / 5 V
• Power Supply mode includes Voltage & Current control with Constant, Scanning & Step-Stair experiments
• Up to five mass flow controllers available
• Includes Furnace Control hardware with redundant over-temperature protection
• Constant or stoichiometric-controlled reactant flow rate
• Zero Volt Capability
• Current, voltage or power control mode
• Continuous real time cell resistance and IR-free voltage measurement by Current Interrupt
• Whole cell voltage plus two high-impedance reference inputs for half-cell data
• Cell main terminals & sense inputs tolerant of non-isolated cell
• Safety features include detection of alarm conditions and automatic hardware shutdown for safe, reliable operation

 Electronic Load:
 Maximum Load Current  5/25/50 A
 Maximum Load Power  100 W
 Minimum Load Resistance  < 2 mΩ (100 mV @ 50 A at load terminals)
 Current Resolution  1 mA for 5/25/50 A
 Current Accuracy  0.3 % of full scale current rating
 Voltage Measurement and Data Acquisition
 Maximum Whole Cell Voltage  20 V
 Maximum Reference Electrode Voltage  9.999 V
 Sense Lead Input Resistance  > 35 kΩ
 Voltage Resolution  I mV
 Voltage Accuracy  ±3 mV ±0.3 % of reading
 Voltage and Current Data Update Rate  100 Hz
 Reactant Gas Control System
 Mass Flow Control  Anode up to 1 SLPM and cathode up to 3 SLPM*.
 Software controlled mass flow controllers. Automatic N2 purge valves on anode and cathode
 Temperature Controllers
 Quantity  (3) Furnace, anode humidifier, cell temp
 Set and Report Accuracy  ±0.25 % of span, ±1 least significant digit
 Sensor Type  Thermocouple, type K (R/S also available)
 Temperature Limit Controller  (1) Furnace over-temp
 Humidifier  Anode only, sparger-type, single passivated 316L W heaters per bottle
 Temperature Range  Ambient to 99 ° C
 Environment
 Operating Temperature  0 – 40 °C
 Power Source  120 V, 50/60 Hz, 900 W
 Enclosure Type  Single bench top enclosure
 Size and Weight  18” H x 11” W x 19” D, 50 lb
 46 cm x 28 cm x 48 cm, 23 kg

Scribner 855 SOFC Installation Video

885 Potentiostat

881 FRA for EIS & HFR

Back Pressure Units

850 Auto Multigas Unit

892e Data Expansion

Fuel Cell Fixture

Gas Mixing Interface

Heated Cuffs

850 Stand-Alone Humidifier

DI Water Tank

หากท่านสนใจกรุณากรอกรายละเอียด

Related Searches:

TESTA 1000 Solar Radiation chamber

highlyprecise and reproducible conditionsfor climatic and temperaturetesting in many industries.

Titrator : TitroLine 7500 KF trace

a compact, easy-to-use coulometric titrator for water determination according to Karl Fischer (KF) with a typical operating range of 1 ppm – 5% water.

TESTA BT – Battery Testing Chambers

battery testing solutions in line with the EUCAR hazard levels, ensuring safe, reliable, and sophisticated testing for energy storage systems.

Titrator : TITRONIC 300

perfect motor-driven piston burette for dosing tasks and manual titration

Chat with us on LINE

เราใช้คุกกี้เพื่อพัฒนาประสิทธิภาพ และประสบการณ์ที่ดีในการใช้เว็บไซต์ของคุณ คุณสามารถศึกษารายละเอียดได้ที่ นโยบายความเป็นส่วนตัว และสามารถจัดการความเป็นส่วนตัวเองได้ของคุณได้เองโดยคลิกที่ ตั้งค่า

Privacy Preferences

คุณสามารถเลือกการตั้งค่าคุกกี้โดยเปิด/ปิด คุกกี้ในแต่ละประเภทได้ตามความต้องการ ยกเว้น คุกกี้ที่จำเป็น

Allow All
Manage Consent Preferences
  • คุกกี้ที่จำเป็น
    Always Active

    ประเภทของคุกกี้มีความจำเป็นสำหรับการทำงานของเว็บไซต์ เพื่อให้คุณสามารถใช้ได้อย่างเป็นปกติ และเข้าชมเว็บไซต์ คุณไม่สามารถปิดการทำงานของคุกกี้นี้ในระบบเว็บไซต์ของเราได้

  • คุกกี้เพื่อการวิเคราะห์

    คุกกี้ประเภทนี้จะทำการเก็บข้อมูลการใช้งานเว็บไซต์ของคุณ เพื่อเป็นประโยชน์ในการวัดผล ปรับปรุง และพัฒนาประสบการณ์ที่ดีในการใช้งานเว็บไซต์ ถ้าหากท่านไม่ยินยอมให้เราใช้คุกกี้นี้ เราจะไม่สามารถวัดผล ปรังปรุงและพัฒนาเว็บไซต์ได้

Save