600 PEM Water Electrolysis Test System

600 Electrolyzer Test System (ETS), Advanced Test System for Research & Development of PEM Electrolyzers

The 600 ETS is a state-of-the-art, full-featured bench-top instrument for detailed evaluation and characterization of PEM electrolyzers. The 600 ETS includes an integrated Power Supply, Potentiostat, Impedance Analyzer for EIS & HFR, and real-time sensors for Product Flow Rate and Cross-over Monitoring. The 600 ETS is ideal for labs requiring detailed control, diagnostic and analysis of a single electrolzyer cell.

Powerful FlowCell-ETS® software offers full control and monitoring of the test cell. Built-in experiments include constant, scanning or step-stair voltage or current controlled measurements. Easy, hands-free switching between control of the voltage or current by the Potentiostat or Power Supply.

• Bench-top, fully integrated instrument for electrolyzer R&D
• 4 current range potentiostat (± 0.07 / 0.7 / 7 / 20 A, ±5 V) for accurate wide dynamic range current measurement
• Software controlled programmable Power Supply for operation up to 100 A / 5 V
• Automated switching between Potentiostat and Power Supply mode
• EIS and HFR (1 mHz to 10 kHz) in Potentiostat mode
• FlowCell-ETS® application software for complete system control, experiment sequencing, graphing and data acquisition
• EIS data compatible with ZView®, the world’s leading impedance analysis & equivalent circuit modelling software
• Integrated back pressure to 2 barg
• N2 purge on Cathode with Supplemental N2 on Anode
• Anode feed water recycling or once-thru operating mode
• In-line high-temperature Ion Exchange cartridge to maintain Anode feed water purity in recycle mode
• Includes safety features: E-Stop, Over Voltage/Current, Over Temperature or Gas Detection shutdown
• Integrated 892e Data Expansion Module for additional 8 temperature + 8 analog inputs, e.g., pressure transducers
• In-line, real-time O2 and H2 product flow rate monitoring

 Cell Connections  4-terminal (I+, I-, V+, V-) & differential Aux (REF)
 Cell Potentiostat:
 Full Scale Current Ranges  ±20 / 7 / 0.7 / 0.07 A
 Current Resolution  0.007% of range
 Current Limit of Error  ±1.0% of range
 Set and Read Voltage vs . WE  > ±5.000 V
 Cell Voltage Sense Lead  Differential w/ driven shields
 Voltage Measurement Resolution  152 μV
 Sense Lead Input Resistance  1.0 GΩ
 Modes of Operation  Constant, Scan, Step-Stair; V and I
 Cell Power Supply:
 Maximum Current  100 A
 Voltage Range  0 – 5.000 V
 Power  Up to 500 W
 Impedance Measurement (Potentiostat Mode):
 Frequency Range  1 mHz to 10 kHz
 Measurement Types  Sweep EIS and single-frequency HFR real-time measurement,
 Whole Cell and Aux
 Cell and Electrolyte Handling:
 Flow Path  All 316 SS
 Feed Water Reservoir  1 L, 316 SS, auto-water fill, conductivity probe
 Feed Water Supply Pump  50 – 400 mL/min, software controlled
 Feed Water Temperature Range  Ambient to 95 oC
 Ion exchanger / Deionizer  In-line water recycling loop
 Back Pressure  Dual, 0-2 barg (0-30 PSIG), Manual
 Cell Temperature Range  Ambient to 120 oC
 Purge Gas  PC-controlled MFC on Negative; Manual on Positive
 Water/Gas Separator/Dehumidifiers  2 (Negative, Positive), condensers & collection tanks
 Product Mass Flow Meters  2 (1 SLM H2, 0.5 SLM O2)
 Additional Data Acquisition (892e):
 Data Acquisition (892e)  8 Temperature + 8 Analog (e.g., 0-5 V, 4-20 mA)
 Options:
 In-Line Gas Sensors  H2 Transmitter for monitoring of H2 in Product O2
 O2 Transmitter for monitoring of O2 in Product H2
 Physical and Environment:
 Operating Temperature  5-35 oC
 Power Source  100-120 or 220-240 VAC, 50/60 Hz
 Size (excluding tubing connections)  53 cm x 53 cm x 90 cm
 Weight  64 kg (140 lb.)

หากท่านสนใจกรุณากรอกรายละเอียด

Related Searches:

TESTA 1000 ตู้สำหรับจำลองการทดสอบการแผ่รังสีจากดวงอาทิตย์

วิเคราะห์และศึกษาข้อมูลเชิงลึกของผลิตภัณฑ์ที่สนใจภายใต้แสงแดด อุณหภูมิและความร้อนต่างๆ ที่สามารถควบคุมได้

Titrator : TitroLine 7500 KF trace

a compact, easy-to-use coulometric titrator for water determination according to Karl Fischer (KF) with a typical operating range of 1 ppm – 5% water.

TESTA BT – Battery Testing Chambers

battery testing solutions in line with the EUCAR hazard levels, ensuring safe, reliable, and sophisticated testing for energy storage systems.

Titrator : TITRONIC 300

perfect motor-driven piston burette for dosing tasks and manual titration

Chat with us on LINE

เราใช้คุกกี้เพื่อพัฒนาประสิทธิภาพ และประสบการณ์ที่ดีในการใช้เว็บไซต์ของคุณ คุณสามารถศึกษารายละเอียดได้ที่ นโยบายความเป็นส่วนตัว และสามารถจัดการความเป็นส่วนตัวเองได้ของคุณได้เองโดยคลิกที่ ตั้งค่า

Privacy Preferences

คุณสามารถเลือกการตั้งค่าคุกกี้โดยเปิด/ปิด คุกกี้ในแต่ละประเภทได้ตามความต้องการ ยกเว้น คุกกี้ที่จำเป็น

Allow All
Manage Consent Preferences
  • คุกกี้ที่จำเป็น
    Always Active

    ประเภทของคุกกี้มีความจำเป็นสำหรับการทำงานของเว็บไซต์ เพื่อให้คุณสามารถใช้ได้อย่างเป็นปกติ และเข้าชมเว็บไซต์ คุณไม่สามารถปิดการทำงานของคุกกี้นี้ในระบบเว็บไซต์ของเราได้

  • คุกกี้เพื่อการวิเคราะห์

    คุกกี้ประเภทนี้จะทำการเก็บข้อมูลการใช้งานเว็บไซต์ของคุณ เพื่อเป็นประโยชน์ในการวัดผล ปรับปรุง และพัฒนาประสบการณ์ที่ดีในการใช้งานเว็บไซต์ ถ้าหากท่านไม่ยินยอมให้เราใช้คุกกี้นี้ เราจะไม่สามารถวัดผล ปรังปรุงและพัฒนาเว็บไซต์ได้

Save